The 11,000 square foot Data Center facility contains everything needed to ensure your mission-critical Internet operation is functioning at the highest perfomance levels.
Connectivity
The network is connected via 10-Gigabit Ethernet Wavelength handoff(s) on redundant/dual-path DWDM fiber-optic transport connections to XO™ Communications and Zayo™ Bandwidth. Verizon™ (Formerly Bell Atlantic PA) and Frontier™ Communications (Formerly Commonweath Telephone – CTSI), fiber is also available in the facility. The network currently connects POPs (Points of Presence) in Scranton, Philadelphia, & NYC. Transit is provided via multiple 10-Gigabit/Gigabit Ethernet transit circuits from Telia™ (http://www.teliasoneraic.com), Cogent™ Communications (http://www.cogentco.com), BTN™/PCCW™ (http://www.btnaccess.com), XO™ Communications (http://www.xo.com), Hurricane Electric™ (http://www.he.net), & Deutsche Telekom™ (http://www.deutschetelekom-icss.com). We also peers with multiple carriers at the New York Internet Exchange™ (http://www.nyiix.net). For redundancy, we are currently running BGP4 (border gateway routing protocol) to maintain the speed and uptime. If one backbone line goes down, it will balance the load to the other(s). If one line gets congested, it will load balance the traffic. NOC is currently the only major data center/co-lo facility within 60-75 miles of the Tier-3 Scranton/Wilkes-Barre PA USA Metro Area.
Failsafe Power Supply
Our Data Center currently has 1200amps 480V & 800amps 208V 3-Phase power currently available from PP&L™ (Pennsylvania Power & Electric). The facility is currently backed up and protected by multiple 275KVA and 160KVA Powerware™ 9315/9395 facility-wide UPS (Uninterruptible Power Supply) systems, which feed PDI™, MGE™, & Liebert™ PDU (Power Distribution Unit) systems. In a very rare case of utility outage, our Cummins™ 250KW & Detroit Diesel™ 580KW & 675KW deisel generators start automatically, taking over for the UPS systems and supplying all necessary power for the facility. The generators interface to the power grids thru Asco™ 7000 & RussElectric™ RTBD automatic transfer panels. With multiple fuel tanks on-site, the generators are capable of running without refueling for approximately 48 hours.
Environment
Precision-controlled raised floor air conditioning systems protect and cool mission-critical servers and equipment in the Data Center. The facility is controlled by multiple 30-Ton APC™/Airflow™, 20-Ton Liebert™, & 20-Ton Data Aire™ dual-compresser redundant systems. These systems provide a virtually dust-free and particle-free computing environment, with temperature, humidity, and air-quality regulation.